<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-04 10-21-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.80 MHz 3/5, 55 dBuV ROCK
Pilot RDS Phase Difference
6.8 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 15 kHz 3158 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,35 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" ROCK " 6288 11 (Rock M) 1 0 1 1 --:--
RT
"Nest "
AF EON
89.9, 93.7, 95.8, 98.8, 104.7, 106.3, 107.0 MHz -
FM Scope Max at: 15 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/03/04 10.20.49 Total samples: 3158 Equivalent time: 0:02:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 7,0 dBr MIN: 2,3 dBr AVE: 4,35 dBr % above 12,2 dBr: 0,0 Last value: 6,8 dBr (2025/03/04 10.20.48) 10.06 10.08 10.10 10.12 10.14 10.16 10.18 10.20 0 2 4 6 8 Pm [dBr]